Building protection
3G HEPAeSORB Filters are better than conventional
(old-fashioned) Hepa air filters as they have a lot
lower air flow resistance and still filtrate also
gases and kill microbes.
3G HEPAeSORB Filters are designed to maintain
healthy indoor air by preventing typical airborne
contaminants, like particulate matter, VOCs,
ozone, and odours, from entering the room air.
Patented 3G technology enables high filtration
efficiency combined with very low pressure
drop ( P/Pa), leading to both very high and
long lasting loading capacity.
They can be installed as an integrated part of the
ventilation system, or stand-alone units.
Filter units that can be moved
with integrated blower / fan and UV-light
Buildings etc.
Product name |
LIFA IAQ M 3G 300 |
LIFA IAQ M 3G 450 |
LIFA IAQ K 3G 450 |
LIFA IAQ K 3G HF |
| Size (exterior) mm |
400*600*850 |
550*750*1050 |
550*550*1500 |
670*670*2000 |
Parts |
| Prefilter |
EU 3 |
EU 3 |
EU 3 |
EU 3 |
| UV-light |
30 mW/cm2 |
50 mW/cm2 |
50 mW/cm2 |
70 mW/cm2 |
| Charger |
10 W |
10 W |
10 W |
20 W |
| Voltage |
6-10 kV |
6-10 kV |
6-10 kV |
6-10 kV |
| 3G Filter bag mm |
particle/active carbon 305*305*250 |
particle/active carbon 450*450*293 |
particle/active carbon 450*450*400 |
particle/active carbon 610*610*550 |
| Blower |
0,155 kW 2600 1/min |
0,225 kW 2700 1/min |
|
|
| 3G Filter bag mm |
particle/active carbon 305*305*93 |
particle/active carbon 450*450*293 |
particle/active carbon 450*450*400 |
particle/active carbon 610*610*550 |
Technical information |
| Airflow |
100 l/s (meas.) |
300 l/s (meas.) |
600 l/s (app.) |
1000 l/s (app.) |
| 360 m3/h |
1080 m3/h |
600 m3/h |
3600 m3/h |
| 212 CFM |
636 CFM |
1271 CFM |
2119 CFM |
| Efficiency particles/gases |
99,99% / 95% |
99,99% / 95% |
99,99% / 95% |
99,99% / 95% |
| Frame |
cart |
cart |
sealed box |
floor box |
- Filtration solutions are equipped either with fixed stump (model k)
or wheels (model m)
- System can be installed as an integrated part of the ventilation system or as a separate unit to filtrate and circulate indoor air
- System (model k) can work simultaneously as an as an integrated part of the ventilation system and as a unit to filtrate and circulate indoor air
- When system is installed as a part of the ventilation system, there is no prefiltrer
- System has an own blower in each unit
- System has to be connected to electricity
- Filtration efficiency has been measured for particles (> 0,1 µm) and gases
- UV-light can be installed as an accessory
- Systems are EMC protected
- When the system is equipped with UV-ligths then the letters UV will be added to the end of product name
|

HEPA air filter efficiency combined with gas filtration and 100% microbe killing efficiency. |
|